| [ Return to Bugs & Features | Roadmap 1.3 | SVN ⇄ GIT ]
STR #3048
Application: | FLTK Library |
Status: | 2 - Closed w/o Resolution |
Priority: | 3 - Moderate, e.g. unable to compile the software |
Scope: | 3 - Applies to all machines and operating systems |
Subsystem: | None |
Summary: | Fl_Help_Dialog is clipping arrows on vertical scrollbar |
Version: | 1.3-current |
Created By: | kdiman |
Assigned To: | AlbrechtS |
Fix Version: | Will Not Fix |
Update Notification: | |
Trouble Report Files:
Trouble Report Comments:
|
#1 | kdiman 07:22 Feb 07, 2014 |
| see screenshot. | |
|
#2 | greg.ercolano 05:01 Feb 08, 2014 |
| Hmm, can't replicate with 1.3.x current.
Also: what scheme are you using?
It's definitely not the default, and even with gtk+ I can't get buttons like that under linux. Do you have one of the alternate scheme patches applied? | |
|
#3 | kdiman 05:20 Feb 08, 2014 |
| Greg, that scheme is oxy. I had thought you will guess about that by view of arrow on the screenshot...
For reproduce: exec fluid, go to help->About FLUID->View License
-- regards | |
|
#4 | greg.ercolano 22:35 Feb 15, 2014 |
| Ok, but unless I'm missing something, we haven't yet integrated oxy into FLTK.
If there's a way to demonstrate the issue as a problem in FLTK as it stands now, then we can address it in this STR. Or if you can show the issue in some other way without the patch applied. Or if you can shrink the issue down to a smaller problem (i.e. change specific lines in FLTK to demonstrate how it's not doing something right to make the problem visible)
But if it's only demonstrable with the oxy patch, then I'd suggest adding this issue to STR#2675 and citing the attachment# that you used to replicate, as we don't yet know if it's a bug in FLTK or the patch.
Let me know if I'm missing something.
FLTK STRs are either bugs in the code base, or RFEs. We don't want to have bug reports against RFE patches that haven't yet been integrated, it's too complicated to track. | |
|
#5 | greg.ercolano 02:05 Feb 16, 2014 |
| BTW, can't replicate with fluid (About Fluid -> View License) because it opens a web browser to view the license.
I did try About Fluid -> Rapid Development With Fluid which opens Fl_Help_View, and the arrows look OK with both the default and gtk+ schemes. You sure this isn't a bug in oxy? | |
|
#6 | greg.ercolano 02:07 Feb 16, 2014 |
| Changing priority to moderate. | |
|
#7 | kdiman 02:27 Feb 16, 2014 |
| > You sure this isn't a bug in oxy? Perhaps that is happening by arrows of oxy are a bit wided than in other themes.
And one more bug: if you push FL_UP arrow on keyboard after shown license dialog, you get disappearing of arrows on the scrollbar... | |
|
#8 | AlbrechtS 10:56 Jan 09, 2019 |
| Since this is a bug report of a custom scheme this can not be fixed in the FLTK library. | |
[ Return to Bugs & Features ]
|
| |